What a heating manifold is and why it leaks
A heating manifold is the metal bar, often chrome or brass, that splits one flow of hot water from the boiler or heat source into several loops of pipe. In a home with underfloor heating it normally sits in a cupboard, under the stairs or in a utility space, with a pair of bars: one sending hot water out and one taking cooler water back. Each loop usually has its own valve, and many have a small flow meter so the installer can balance the rooms.
Because everything joins in one place, a manifold has a lot of joints for its size. Each loop connects through a compression fitting or a push-fit adapter. Each flow meter has seals. There are air vents, drain points, isolation valves and an actuator at the head of each valve. Any of these can weep. In our experience, and this is a practitioner view, not a measured rate, the seals and threaded joints are a more likely source than the metal body itself.
A manifold leak is also easy to miss. Water runs down the chrome, drips into the cupboard base and either evaporates or is soaked up by whatever is stored there. The first sign is often a boiler or system pressure that keeps falling, a damp smell in a utility cupboard, or white or orange staining on the fittings. This page describes that kind of job. It is not a record of a past customer and it makes no promise about how long your job will take.
Signs that point at the manifold
None of these proves the manifold is the cause, but together they make it a sensible first place to look.
- The heating pressure gauge on the boiler or filling loop drops over days and needs topping up, with no obvious leak at a radiator or the boiler.
- There is staining, green or white crust, or a damp patch on or under the manifold, or on the floor of its cupboard.
- One room is slow to warm up or one loop is cold while the others are hot. Air or a restricted valve can cause that, so it is a clue and not a verdict.
- The system makes gurgling noises, which can mean air is being drawn in where water is escaping.
- The cupboard smells musty, or a timber floor or skirting next to it is stained or lifting.
If the pressure keeps dropping and you cannot see a leak anywhere, you may have a leak in a floor loop, a radiator pipe or a hidden joint. The manifold is only one candidate. Our page on finding a hidden leak in one hour covers how we separate the likely places.
Safe checks before you call
- Open the manifold cupboard and clear out anything stored there. Switch on a torch and look at the bars, the flow meters and the loop connections. Do not touch wiring or the actuator heads with wet hands.
- Wipe each joint with a dry paper towel and watch for a fresh bead of water. Fresh water at a joint tells you far more than an old stain.
- Take a phone photo of the gauge reading on the boiler or filling loop and note the date. A second reading a day later shows whether the pressure is falling.
- Look at the floor and the base of the cupboard for a damp patch, and feel the carpet or boards nearby.
- Do not drain the system, top it up repeatedly or loosen fittings to see what happens. Opening a heating system lets in air and can make a small weep into a larger one.
If water is running steadily, turn off the heating, shut the filling loop if there is one and call us. If it is near electrical equipment, keep clear and switch off at the consumer unit if it is safe to reach. Our guide to how to drain down your water system is written for the cold water side, so treat it as background only. A sealed heating circuit works differently.
What the first hour can do
The first hour is priced as £100 for the first hour, then £150 an hour, in half hours, with everything included: tracer gas, acoustic detection, thermal imaging, an endoscopic camera inspection, a trace and access report for your insurer and a written quote for the remedial works. It is a useful way to take a decision on a manifold because the likely places are close together. Here is what we aim to do in that time. It is a plan, not a guarantee.
- Look and listen. We inspect every joint by eye, with a torch and a mirror where needed, and note any staining, crust or fresh moisture.
- Check pressure behaviour. We read the system pressure and look at how it has behaved, then decide whether to isolate loops one at a time.
- Isolate and test. Where the loop valves close properly, we can shut off one loop and see whether the pressure holds. That helps tell a leak at the manifold from a leak in a loop.
- Use tracer gas where it helps. Tracer gas, a harmless hydrogen and nitrogen mix that is lighter than air, can be pushed through a closed circuit. A detector then picks up gas escaping at a joint that is too small or too hidden to see. In our practice this has helped at manifolds with several tight joints, but it is a tool and not a certainty.
- Confirm the source. We mark the joint or fitting that is leaking and photograph it for the written report.
- Quote the fix. You get a written quote for the repair, separately from the detection. Sometimes the repair is a seal or a tightened fitting and can follow quickly if we carry the part and the loop can be isolated.

The photo above shows the set-up: an opened manifold cupboard, a probe held at the fittings and a handheld detector. The detector does the sniffing so that nobody has to guess which of a dozen joints is weeping.
What the evidence can look like
A written report is only useful if it shows where the leak is. For a manifold that usually means a photo of the joint, a note of what the test showed and a short description of the fix. Two kinds of evidence are common. One is a gas detector reading taken at the fitting. The other is simple visual evidence: staining, drips and wet metal.

In this photo the detector screen shows a high reading beside an opened manifold. A high reading near a joint is a pointer, not a verdict. Gas can drift in a cupboard, so a reading is checked by moving the probe from joint to joint and seeing where it peaks. That is why a second look matters.

The third photo shows what a found leak can look like when it is visible: orange staining and drips on a chrome manifold around the flow meter fittings. Staining like this is a clue that water has been escaping slowly for some time. Not every leak leaves a mark, which is why we test instead of relying on appearance.
What the first hour tends to give you
| What we find | What the hour can do | What may need longer |
|---|---|---|
| A weeping flow meter, adapter or air vent | Confirm it, photograph it and quote the part and fit | Draining and refilling the circuit, if the loop cannot be isolated |
| A loose or perished compression fitting | Confirm it and quote the repair, sometimes a quick tighten or reseat | A new fitting if the olive or pipe end is damaged |
| A faulty loop valve or actuator | Confirm the part is at fault | Replacing it, which may need the circuit drained |
| Pressure loss with a dry manifold | Rule the manifold in or out, which is useful in itself | A search of floor loops, radiators and pipework |
| A leak in an underfloor loop | Narrow down which loop is losing pressure | Locating it under the screed, which can need thermal imaging and may need a further visit |
Ruling the manifold out is a real result. It saves you replacing parts that are fine and points the search at the right part of the system.
What usually needs longer than an hour
We would rather say this plainly than let you expect the wrong thing. Some manifold jobs do not fit in an hour, and an hour only buys what it buys.
- Poor access. A manifold behind plasterboard, inside a built-in unit or at the back of a deep cupboard can take time to open up safely, and the time counts.
- Loops that do not isolate. If a valve is seized or leaking by, we cannot prove a loop is holding, and testing takes longer.
- A leak in the floor. A pipe loop buried in screed or under a finished floor is a different job from a joint on a bar. It may need a pressure test of each loop, thermal imaging and then a decision about opening the floor. Our page on thermal imaging leak scans explains that side.
- More than one leak. Finding the first weeping joint does not rule out a second, and a careful check can add time.
- Parts. If the right seal, valve head or adapter is not on the van, the repair waits for the part even if the leak is found within the hour.
We call you before the survey goes past 3 hours, so there is no surprise on the bill. A 2.5 to 3 hour survey is typically £325 to £400.
What it costs and what is included
Standard leak detection is £100 for the first hour, then £150 an hour, billed in half hours after the first. That means two hours is £250 and three hours is £400. Everything is included: tracer gas, acoustic detection, thermal imaging, an endoscopic camera inspection, a trace and access report for your insurer and a written quote for the remedial works. We call you before the survey goes past 3 hours. No VAT charged, and there is no parking charge.
Heating and underfloor heating work has its own line on the pricing page, shown as £200/hr. Please check that page, or tell us the kind of system when you report the leak, so that the rate we quote is the right one before we start. For a longer look at what the survey covers, see what leak detection does and does not include and the page on the first hour.
No find, no fee: if a leak is present and we do not find it, you pay nothing. Repairs are quoted separately in writing once the leak is found. We do not publish a repair price list, because a seal and a drained, refilled circuit are not the same job.
After the hour: the repair quote and your options
You get the result in writing, with photos and a quote for the repair. You are not obliged to accept the quote, and the report is yours. You can ask us to do the repair, ask another plumber or heating engineer to quote from the report, or ask us to hold off until you have spoken to your installer or your landlord.
If your underfloor heating is under a guarantee or a maintenance agreement, read it before anyone opens the manifold, because some agreements expect the installer to do the work. If you are a tenant, tell your landlord or agent first and check who must repair under the tenancy.
If the leak has damaged a floor or a wall, a written report can help when you talk to an insurer, but whether an insurer pays depends on the policy and is its decision. Our page on the report for an insurance claim explains what we put in it. For an overview of methods and what each is for, see the leak detection survey page and the guides.
To arrange a visit, report a leak and tell us what you can see, what the pressure gauge is doing and where the manifold is. The more we know about access, the better we can say what the hour is likely to achieve. Related one-hour jobs are on the one-hour leak jobs page.