What a thermal imager does and does not do
A thermal imager is a camera that reads surface temperature instead of light. The screen paints warmer areas in one colour and cooler areas in another. In leak work it is useful for two reasons. A pipe carrying hot water, such as an underfloor heating loop or a hot supply, can show up as a warm line on a floor. And a patch of wet plaster or board can sit at a different temperature from dry material around it, because water changes how a surface warms and cools.
What the camera does not do is see water. It sees temperature differences on the surface. A cold patch can be damp, but it can also be a cold bridge, a draught, a thinner layer of plaster or a window reveal. A warm line can be a heating pipe working normally. So the picture is a lead, not a verdict. This is a practitioner view of the method, and the details change with the building, the weather and the heating.
When a thermal scan is the right first move
Thermal imaging earns its place when the leak is hidden but the area is large and the surface is not tiled in a way that blocks heat. These are the situations where we would normally reach for it early.
- Underfloor heating pipes that you suspect are losing water, where the first job is to map where the loops run. The image can show warm pipe runs and sometimes a patch where one loop looks different from the others.
- A hot water supply that you think is leaking under a floor, because the leaking water can warm the floor above it in a small area while the system is running.
- A damp patch on a wall or ceiling where the source is unclear, to see how far the affected area spreads before a moisture meter confirms it.
- A bathroom or shower area, to check the edges of an enclosure and the wall around it for a cold, wet-looking zone.
- A search that needs to be non-invasive, for example in a finished room where you do not want holes made until there is a good reason.
Our page on non-invasive leak detection sets thermal imaging alongside the other methods, and moisture mapping and damp diagnosis covers how a damp patch is measured and recorded.
What the image can show
Here is a thermal screen over a floor with a heating system running. The warm lines are pipe runs, shown in red against a cooler blue background. The loops are easy to follow, which is the use of a scan like this: it gives a map of where the pipes go so that anyone testing or opening the floor does so in the right place.

A closer view of the same kind of image shows the looping layout more clearly. A tidy, even pattern suggests the pipe is where it should be. A gap, a break in the pattern or a patch that looks different is a point to look at harder, not a confirmed leak.

A scan can also come back clean. The next image shows an imager pointed at the corner of a glass shower enclosure, and the screen is a uniform blue. No temperature difference in that view means the camera found nothing to point at in that spot at that moment. It does not prove the area is dry, and it is a reason to try another method such as a moisture meter or a dye test.

What the first hour can do
The first hour is priced as £100 for the first hour, then £150 an hour, billed in half hours, and everything is included: tracer gas, acoustic detection, thermal imaging, an endoscopic camera inspection, a trace and access report for your insurer and a written quote for the remedial works. A scan sits inside that. Here is the plan, and it is a plan, not a guarantee.
- Talk it through. We ask where the damp or the pressure loss is, when it started and what the heating or hot water has been doing. The right conditions matter, because a scan of a cold, inactive pipe shows little.
- Set up the conditions. For a heating or hot water pipe the system needs to be running so the pipe is warmer than the floor above. We may ask for the heating to be on before we arrive.
- Scan the area slowly. We sweep floors, walls, ceilings and edges, and compare each view with a dry reference area nearby.
- Check anything that looks different with a second tool, such as a moisture meter, or tracer gas, or an acoustic check on a pressurised pipe.
- Mark it up and report. Anything confirmed is photographed and marked for the written report, and you get a quote for the repair.
The thermal image is the way in. The confirmation comes from the second method. Our page on the tracer gas leak test explains one of those, and pressure testing pipework explains another.
What a scan is good and poor at
| Situation | Thermal scan tends to | Usual next step |
|---|---|---|
| Underfloor heating loops, system running | Map where the pipes run and show patterns | Pressure test each loop, then confirm the point |
| A hot pipe leaking under a floor | Sometimes show a warm patch above the leak | Acoustic or gas check, then a quote to open the floor |
| A damp wall or ceiling | Show the extent of a cooler patch | Moisture meter reading and a look for the source |
| Cold supply pipe | Often show little, because there is little temperature difference | Acoustic detection or tracer gas |
| Foil, shiny or heavily tiled surfaces | Give a poor or misleading image | A different method |
| Thick screed or insulation over the pipe | Show a faint or smoothed image | Pressure tests and a decision on opening up |
That table is why we say a scan narrows a search. It saves you from guessing, but it seldom ends the search on its own.
What usually needs longer than an hour
- A large or multi-room area. Scanning every wall and floor of a house takes time, and the time counts on the clock.
- Cold pipes. If the leak is on a cold supply, the image may show little and the job moves to other methods.
- Getting the system up to temperature. If a heating system takes a long time to warm the floor, the scan waits for it.
- Poor surfaces. Reflective floors, rugs, furniture and thick coverings can block or distort the view.
- Weather and heating. A building in strong sun or one with the heating off can give weaker contrast. We may suggest a return visit in better conditions.
- Several candidate areas. A scan that raises three possibilities needs time to confirm each.
We call you before the survey goes past 3 hours. A 2.5 to 3 hour survey is typically £325 to £400, which is £250 for two hours and £400 for three. For how long a survey tends to run and why, read how long leak detection takes.
Before you call: simple things that help
- Note where the damp is, when you first saw it and whether it changes with the heating or when a tap is run.
- If you suspect a heating leak, take a photo of the system pressure gauge and check it again the next day.
- Put the heating on before we arrive if we ask you to. A cold floor gives a poor image.
- Clear furniture and rugs from the area if you can do so safely, so the camera can see the floor.
- Do not drill, chase or lift anything to look for the leak yourself. Opening a floor without a location can cause more damage than the leak.
If water is escaping now, close the stop valve that feeds it, which Thames Water says is usually under the kitchen sink, and read how to turn off your mains water. If the leak is on a heating system, turn the heating off.
Cost, the report and what happens next
Standard leak detection is £100 for the first hour, then £150 an hour, with tracer gas, acoustic detection, thermal imaging, an endoscopic camera inspection, a trace and access report for your insurer and a written quote for the remedial works all included. No VAT charged, and there is no parking charge. Heating and underfloor heating leaks have their own line on the pricing page, shown as £200/hr, so check it or tell us the system when you report a leak. No find, no fee: if a leak is present and we do not find it, you pay nothing.
Mains and supply pipe leak detection is a fixed £450, however long the job takes. Repairs are quoted separately in writing once the leak is found, and we do not publish repair prices because every fix is different. You are not obliged to accept a quote, and the report is yours.
A written report with photos can help when you talk to an insurer, but whether an insurer pays depends on the policy and is its decision. Our page on the leak detection survey explains the full process, the first hour page explains what the opening hour buys and the one-hour leak jobs page lists the others. If the scan points at a manifold, the heating manifold leak check is the next read, and our guides cover the rest.