What “under the house” means in London
“Slab leak” is an American phrase for a leak in a pipe cast into or under a concrete floor. In London the picture is more mixed. Many Victorian and Edwardian houses have suspended timber floors over a void, so pipes run in the void or in the joists. Extensions, garages, conversions and newer homes more often have a solid concrete floor, sometimes with a screed on top and pipes or underfloor heating inside it. Ground floor flats can have either. Which one you have changes how a leak shows itself and how it is found, so check first what your floor is made of.
| Floor type | Where pipes usually are | What a leak does |
|---|---|---|
| Suspended timber floor | In the void beneath, clipped to or passing through joists | Water drips to the void and soil, so the surface may stay dry for a long time; timber can stay damp, and smells and fungus can develop |
| Solid concrete floor, pipes under the slab | Buried in the ground or bedding beneath the slab | Water goes into the ground, then can rise through gaps and joints; damp shows late and in odd places |
| Solid floor with screed and pipes in the screed | Heating or hot water pipes in the screed layer | The screed holds water; damp spreads, floor finishes lift and heat can leave a warm patch |
| Underfloor heating | Loops in screed or in a timber floor | Boiler pressure falls; wet or warm patches can show, but often not at the point of the leak |
We have not found a published source that says how common each floor type is across London, so we do not give percentages. The practical point is that the owner usually knows which floor they have, or can tell by tapping and looking: a hollow sound and airbricks on the outside wall suggest a void, while a solid sound and no airbricks suggest concrete. If in doubt, ask the person who surveyed the property when you bought it.
What you might notice

Under-floor leaks are slow to show. These are the signs we would take seriously, roughly from most reliable to least.
- A water meter that moves with every tap and appliance off and the inside stop valve closed. Thames Water’s published test says movement means a leak between the meter and the inside stop valve. If the valve is closed and the meter still moves, the leak is on the incoming pipe, which may run under the floor.
- A boiler or heating system that keeps losing pressure and needs topping up, with no visible drip. That points at the heating circuit rather than the cold mains, and heating pipes in a floor are a prime suspect.
- A floor that feels warm or hot in one patch when the heating is off, or warmer than the rest when it is on. That can be a hot water or heating pipe leaking or simply a pipe running close to the surface, so it is a prompt to investigate, not a conclusion.
- Damp or discoloured skirting, a musty smell, mould on a wall or lifting laminate, vinyl or timber. Do not assume it is the pipe: condensation, rising damp and a leaking appliance cause the same marks. Moisture mapping and damp diagnosis explains how to tell them apart.
- The sound of running water when the house is quiet. It may be a pipe under the floor, or a cistern or tap, so use it as a prompt to test.
- Cracks or a floor that has settled in a pattern, with no other explanation. A persistent leak can wash out or soften ground beneath a floor, but cracks have many causes. See the section on structure below before worrying.
- A higher metered bill you cannot explain, or low pressure at the taps that are fed straight from the mains.
Cold mains, hot water or heating? Work this out first
The pipe type decides the method, the cost and the engineer, so a few cheap checks are worth the half hour. Do them in this order and write down what you find.
- Run the meter test. Switch everything off, close the inside stop valve, read the meter, wait 30 minutes and read again. If it moves, the cold mains side has a leak. The method is Thames Water’s, read on 24 November 2026; see how to do a water meter leak test for the longer version.
- If the meter does not move, open the stop valve again and watch the meter with every tap off. Movement now, but not with the valve shut, is unusual; check for a running cistern or tap, and a leaking appliance feed.
- If the meter is still, look at the heating. A sealed system with a pressure gauge on the boiler that falls week by week points at a heating leak. Note the pressure and the date. Topping up is a job to do only following your boiler’s own instructions; if you do not know how, ask a heating engineer.
- Compare hot and cold. If you can, check whether the dampness appears only when the hot water or heating has been running. That is a practitioner’s clue and not a diagnosis.
| Result | Most likely system | Next step |
|---|---|---|
| Meter moves with house shut off | Cold mains supply pipe | Locate the pipe route; survey; see underground supply pipe leak |
| Meter still; boiler pressure falling | Heating circuit, flow or return pipes, possibly in a screed | Heating leak survey; see the cost section below |
| Meter still; pressure steady; damp after hot water use | Hot water pipe or an appliance connection | Targeted survey with thermal imaging and moisture mapping |
| Meter still, pressure steady, no pattern | Not a pipe: look at condensation, rain ingress, a drain, damp | Moisture mapping before any plumbing work |
What not to do
- Do not drill, core or chase into a floor to “find the pipe”. You may hit the pipe you are trying to save, a heating loop or an electrical cable, and you will pay for the repair and the reinstatement.
- Do not lift flooring all over the house. Dry rooms and wet rooms look alike under laminate. Lift as little as the survey tells you to.
- Do not run the heating hard on a floor you think is leaking. Check first, or leave it off; a leaking heating pipe loses water and can drive up the bill.
- Do not add a heating “leak sealer” without asking a heating engineer or checking your boiler’s manual first.
- Do not ignore it. A concealed leak can run for weeks. Thames Water’s arranging a repair page says a confirmed leak on your property should be repaired within four weeks and that it can serve a notice if not.
- Do not repair or paint over damp marks before the cause is found. Records help insurers and the allowance.
How a leak under a floor is found, and what each method cannot do
The goal is a spot on the floor plan the size of a small hole, not “somewhere in the kitchen”. Methods are combined because each has blind spots.
| Method | What it does | Limits |
|---|---|---|
| Pressure and isolation tests | Isolates a section of pipe and sees whether it holds pressure, to say which circuit leaks and sometimes which branch. | Tells you which pipe, not where. Needs isolation valves that work. |
| Thermal imaging | Shows temperature differences on a floor surface. Good for hot water and heating pipes and for warm damp patches. | Cold mains pipes under a thick slab give little contrast. Floor coverings and furniture reduce what it can see. Not a way of seeing through concrete. |
| Moisture mapping | Maps damp across floors and walls to show the wettest area. | Shows wet, not source. Water can travel under a floor before it shows. |
| Acoustic listening and correlation | Listens for escaping water on the pipe and floor. | Hard in noisy houses and with plastic or heavily lagged pipes; very small leaks are quiet. |
| Tracer gas | A harmless hydrogen and nitrogen mix is introduced into an isolated pipe and detected at the floor surface where it escapes. | Thick or sealed screed, tiling or dense concrete can slow or spread the gas, so the reading may be a zone, not a point. Included in the price. |
| Pipe tracing | Follows a pipe route so you know where it is before you open anything. | Less useful for pipes inside a screed that you already know the layout of; very useful for a pipe entering under a slab. |
These descriptions of how each method behaves are practitioner experience and not published standards, and results depend on the floor build. A result that narrows the leak to a small area is the normal outcome; pinpointing to the centimetre is not guaranteed, and a small access hole is still likely. See non-invasive leak detection and what happens on the day.
If the house is a Victorian or Edwardian terrace with a timber floor, water leaks in Victorian and Edwardian London houses goes into what older plumbing does. If the problem is below ground level, see basement and cellar water leaks.
Can a leak damage the structure?
It can, depending on the ground and the size and age of the leak. Water escaping under a floor for a long time can soften or wash away fine soil under a slab or footings. A slow leak in a dry house is unlikely to do that quickly, but we have no published source we can cite on how long it takes in London clay or gravel, and we will not give a number.
- If you can see new, widening cracks, doors that stick or a floor that has dropped, tell your insurer and ask for a structural engineer’s view. A leak detection survey cannot tell you whether a building is moving.
- Do not let that stop the leak being found. Stopping the water is the first thing any structural opinion will want.
- Keep dated photographs and meter readings, which help an insurer and a repairer.
What it costs to find the leak
The price depends on which system leaks. Standard leak detection, using thermal imaging and moisture mapping, is £150/hr and a typical visit comes to £325 to £400. Mains and supply pipe tracing is a fixed £450, however long the job takes. Heating and underfloor heating leaks are £200/hr, typically £400 to £800. Tracer gas and the written report are included in the price. No VAT charged.
We quote the price first. That is the cost of finding the leak. Repair, including breaking out a floor and reinstating it, is quoted separately in writing, because the work depends on what is found. See pricing, how we price and how long leak detection takes. If your insurer is paying, the report format matters; see leak detection report for an insurance claim.
Who deals with it, and what about insurance?
- Inside the house, the pipework and the floor are the owner’s, or in a tenancy the landlord’s to keep in repair. Under section 11 of the Landlord and Tenant Act 1985 a landlord must keep the water supply installations in working order in covered tenancies, which GOV.UK describes as including pipes.
- Leaseholders: the lease decides who handles repairs, and for a ground floor flat that can include a shared pipe beneath it. Ask your freeholder or managing agent.
- The incoming supply pipe from the boundary into the house is the owner’s too, even where it runs under the floor. Thames Water describes it as generally the owner’s, up to the point where it meets its own pipe. Only a fault on the water company’s side is theirs; see who is responsible for a water leak.
- Insurance. Many policies include trace and access cover for finding a hidden leak, but the two insurers we read both tie it to damage caused by escaping water, and wording differs. Some insurers want to agree before work starts. Read does home insurance cover water leaks and gradual leak or sudden escape of water claims. We give a written report; whether your insurer accepts it is its decision.
Thames Water recommends WaterSafe approved contractors for hidden leaks. We are not on the WaterSafe register, and you can use any competent contractor.
To get a figure for your floor, report a leak with a few lines on what you have seen, or ring 020 3961 5444. More guides are in the guides hub.